4/28/2023 0 Comments Lilyview manualIf we find any, we delete them and, if necessary, take action against whoever is responsible.Īnyone else who spots something suspicious can always report it to our Customer Service team, so our Fraud team can investigate. We have people and automated systems that specialise in detecting fake reviews submitted to our Platform. To edit a review you’ve already submitted, please contact our Customer Service team. You can review an Accommodation that you booked through our Platform if you stayed there or if you arrived at the property but didn’t actually stay there. Note that guests submit their subscores and their overall scores independently, so there’s no direct link between them. In addition, guests can give separate ‘subscores’ in crucial areas, such as location, cleanliness, staff, comfort, facilities, value for money and free Wi-Fi. To get the overall score that you see, we add up all the review scores we’ve received and divide that total by the number of review scores we’ve received. Press key twice, all the settings will be restored to Fctory Set (see System parameter table).Each review score is between 1-10. Keep P key and key depressed simultaneously for 3 seconds, controller displays “UnL”. When U40 = 1, there will be beeping warning, and display of warning code if any problem. When U40 = 0, there is no beeping warning, only display the warning code if any problem. Do not install or dismount sensor under power supplied. When the sensor is not connected well, or broken, display “E1”, R1 will be de-energized. is not accurate enough, we could calibrate by setting the deviation to U13. high protecting hysteresis 0.0~20.0℃ Room-temp Set-point – U15, stop warning Sensor high protecting point (relative value) 0.0~20.0℃ If Room-temp ≥ Set-point + U16, for U19 protecting exhausting on, R5 energized 0.0: disable Temp. high warning point (relative value) 0.0 ~ 99.9℃ If Room-temp ≥ Set-point + U14 warning (display Hi, buzzing) If Room- temp Set- point – U15 stop warning 0.0: disable Temp. System parameter table Code Function Range Remark Factory Set U10 Control mode CO/HE CO: Cool HE: Heat HE U11 Hysteresis 0.1 ~ 20.0℃ 0.1 U12 Delay protection time for Temp. When there is problem, the code and the room-temperature will display alternatively Code Remark E1 Sensor failure, short or open Hi High temperature alarming Lo Low temperature alarming Power up (Reset) displayĭisplay the following information consecutively: U16 H/C Temperature output R1 energized R1 de-energized R1 under delay protection, ref. R3 and R4 will not switch any more T2 R5 status R5 energized for T2 R5 de-energized R5 energized for over hot protection, ref. Set-point - Slow blink: Setting system parameterįast blink: the times of R3 or R4 status changes has reached U24. Lamp Set blinks in 2Hz Lamp Lamp Function On Off Blink Set Set set-point to switch timer 1’s outputs (R3/R4) status Set value up Short press to display for 2 sec. to set set-point Set value down Keep depressed for 5 sec. to set system parameters S Keep depressed for 3 sec. Keypad and Display Key Key Function 1 Function 2 P Keep depressed for 3 sec. Besides the function introduced in Feature, it has: Heating / Cooling mode option, Temperature output delay protection, Over temperature warning,īuzzing hint and warning.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |